Solar inverter not producing: where to start

An inverter that is on but not producing usually has a code, a state, or a shutdown reason. This guide maps the symptom to the codes to check first, across SolarEdge, Fronius and Victron.

Start from what the inverter or its app actually shows, not from guesswork. The display (or the monitoring portal) reports one of three things: a status/state code (what the inverter is doing), an error code (why it stopped), or a plain-language shutdown reason.

Step 1 — read the state, not just the error

A Fronius inverter sitting at state 307 or a SolarEdge inverter in "night mode / off" may simply be waiting. Confirm the DC input voltage and the AC grid are present before assuming a fault. A Victron charger that shows no error but is not charging may be in float, absorption, or low-battery protection.

Step 2 — match the code

  • Fronius: state codes (102, 103, 306, 307…) describe the operating point; error codes describe faults.
  • SolarEdge: display codes such as isolation and grid faults appear with an error banner in the monitoring portal.
  • Victron: VE.Bus inverters report VE.Bus Error N; MPPT charge controllers report Err N.

Step 3 — the three most common causes

  1. Grid / AC-side fault: voltage or frequency outside limits, or a relay test fault. Check the AC wiring and grid settings with the system isolated.
  2. DC / PV-side fault: isolation or ground fault, PV over-voltage, or low DC. Check array wiring and panel isolation.
  3. Protection trip: over-temperature, overload, or battery protection. Reduce load, clear obstructions, and confirm battery temperature/voltage.

Every code page in this dataset carries the manufacturer source and a "qualified installer only" notice. If the fault touches the AC grid connection, the battery bank, or an internal power stage, stop and escalate.

FAQ

Why is my solar inverter on but producing nothing?

Most often it is a protection trip or a grid/DC-side condition, reported as a status code, an error code, or a shutdown reason. Read the display or app, match the code, and check the AC grid and DC/PV sides with the system isolated.

What does a Fronius state code mean?

Fronius state codes describe the operating point (startup, running, standby, error). The exact meaning is in the Fronius documentation cited on the brand hub.

When should I stop and call an installer?

If the fault touches the AC grid connection, battery bank, DC bus, or an internal power stage, or if you are not qualified to isolate the system, stop and escalate.

Independent and unofficial. General diagnostic guidance, not a substitute for the manual for your exact model.