SMA fault codes

53 verified codes, each with a cited source, likely causes, checks, parts and safety notes.

CodeMeaningSeriesAccess
1001L / N swappedSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
101Grid incident - grid voltage or grid impedance too highSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
102Grid incident - grid voltage or grid impedance too highSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
103Grid incident - grid voltage or grid impedance too highSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
104Grid incident - grid voltage or grid impedance too highSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
105Grid incident - grid voltage or grid impedance too highSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
1101Installation fault - check connectionSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
1302Waiting for grid voltage - grid connection installation errorSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
1501Reconnection fault gridSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
202Grid incident - utility grid down / AC cable damaged / grid voltage too lowSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
203Grid incident - utility grid down / AC cable damaged / grid voltage too lowSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
205Grid incident - utility grid down / AC cable damaged / grid voltage too lowSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
206Grid incident - utility grid down / AC cable damaged / grid voltage too lowSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
301Grid incident - ten-minute average grid voltage exceededSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
302Temperature AC voltage - power limited by high grid voltageSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
3303Unstable operationSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
3501Insulation failure - check generatorSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
3601High leakage current - check generatorSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
3701Residual current too high - check generatorSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
3801Residual current too high - check generator (DC overcurrent)SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
3802Residual current too high - check generator (DC overcurrent)SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
3901Waiting for DC start conditions - start conditions not metSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
3902Waiting for DC start conditions - start conditions not metSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
401Grid incident - stand-alone grid or large frequency changeSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
404Grid incident - stand-alone grid or large frequency changeSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
501Grid incident - grid frequency out of rangeSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
507Temperature AC frequency - power limited by high frequencySMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
601Grid incident - DC proportion in grid current too highSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
6501Self-diagnosis - overtemperatureSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
6502Self-diagnosis - overtemperatureSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
6509Self-diagnosis - overtemperatureSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
6512Minimum operating temperature not reachedSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
6603Self-diagnosis - overcurrent grid / overvoltage intermediate circuitSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
6604Self-diagnosis - overcurrent grid / overvoltage intermediate circuitSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
6801Self-diagnosis - input A / input B defective (polarity error)SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
6802Self-diagnosis - input A / input B defective (polarity error)SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
6901Self-diagnosis - input A / input B defective (polarity error)SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
6902Self-diagnosis - input A / input B defective (polarity error)SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
7001Fault sensor interior temperatureSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
7002Fault sensor interior temperatureSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
701Frequency not permitted - check parameterSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
7701Self-diagnosis - interference deviceSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
7702Self-diagnosis - interference deviceSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
7703Self-diagnosis - interference deviceSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
8003Temperature deratingSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
8708Timeout in communication for active power limitationSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
8709Timeout in communication for reactive power / cos phi setpointSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
8710Timeout in communication for reactive power / cos phi setpointSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
9002SMA Grid Guard code invalidSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
9003Grid parameter lockedSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)self-check
9007Abort self-testSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
901PE connection missing - check connectionSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified
9101AC voltage calibration failedSMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)qualified