Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. Read the safety model.
Growatt SPF 3500/5000 ES off-grid solar inverter

Growatt 20: BMS communication error (warning)

confidence: verifiedchecked 2026-11-21
Quick answerGrowatt 20 means A lithium battery cannot communicate with the inverter (warning)..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

A lithium battery cannot communicate with the inverter (warning).

Likely causes

  • Wrong communication line between inverter and battery
  • Wrong BMS protocol setting

What to check

  1. Check the communication line between the inverter and battery
  2. Check the BMS protocol type setting

Parts implicated

BMScommunication cable
Sources (verbatim):

Paraphrased; verify against the manual for your exact model and serial number.