SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
SMA 104: Grid incident - grid voltage or grid impedance too high
Quick answerSMA 104 means Events 101, 102, 103, 104 and 105 all report the same thing: the grid voltage or grid impedance at the inverter's connection point is too high, so the Sunny Tripower has disconnected from the utility grid. SMA's corrective measures are to verify that the grid voltage stays permanently inside the permissible range and, where the local grid is responsible, to have the grid operator adjust the voltage at the feed-in point or change the monitored operating limits..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
Events 101, 102, 103, 104 and 105 all report the same thing: the grid voltage or grid impedance at the inverter's connection point is too high, so the Sunny Tripower has disconnected from the utility grid. SMA's corrective measures are to verify that the grid voltage stays permanently inside the permissible range and, where the local grid is responsible, to have the grid operator adjust the voltage at the feed-in point or change the monitored operating limits.
Likely causes
- Grid voltage above the permissible range at the connection point
- High grid impedance on a weak or long grid connection
- Monitored operating limits not matching the local grid conditions
What to check
- Check whether the grid voltage at the connection point is permanently within the permissible range
- If local grid conditions keep it out of range, ask the grid operator to adjust the feed-in voltage or the monitored operating limits
- If the voltage is in range and the message persists, contact SMA Service
Parts implicated
grid connection
Sources (verbatim):
- https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (manual, retrieved 2026-11-21) p. 81
“Explanation: The grid voltage or grid impedance at the connection point of the inverter is too high. The inverter has disconnected from the utility grid.”
Paraphrased; verify against the manual for your exact model and serial number.