SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

SMA 1101: Installation fault - check connection

confidence: verifiedchecked 2026-11-21
Quick answerSMA 1101 means A second line conductor has been connected to the neutral terminal N. The manual's corrective measure is to connect the neutral conductor to N, which means correcting the AC terminal wiring at the inverter..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

A second line conductor has been connected to the neutral terminal N. The manual's corrective measure is to connect the neutral conductor to N, which means correcting the AC terminal wiring at the inverter.

Likely causes

  • Two line conductors landed on N
  • AC terminal wiring error at installation

What to check

  1. Isolate the AC supply and prove dead
  2. Connect the neutral conductor to N
  3. Re-check the terminal assignment before re-energising

Parts implicated

AC wiringAC terminal