SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

SMA 1302: Waiting for grid voltage - grid connection installation error

confidence: verifiedchecked 2026-11-21
Quick answerSMA 1302 means The inverter cannot see a complete AC connection because L or N is not connected, so it waits for the grid voltage. SMA tells the installer to ensure the line conductors are connected, the miniature circuit breaker is on, and the AC cable is undamaged and correctly connected..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

The inverter cannot see a complete AC connection because L or N is not connected, so it waits for the grid voltage. SMA tells the installer to ensure the line conductors are connected, the miniature circuit breaker is on, and the AC cable is undamaged and correctly connected.

Likely causes

  • Line or neutral conductor not connected
  • Miniature circuit breaker switched off
  • Damaged AC cable or incorrect connection

What to check

  1. Ensure that the line conductors are connected
  2. Ensure that the miniature circuit breaker is switched on
  3. Ensure that the AC cable is not damaged and is connected correctly

Parts implicated

AC wiringAC circuit breaker
Sources (verbatim):

Paraphrased; verify against the manual for your exact model and serial number.