SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
SMA 302: Temperature AC voltage - power limited by high grid voltage
Quick answerSMA 302 means The inverter has deliberately reduced its power output because the grid voltage is too high, in order to help grid stability. SMA advises watching how often the grid voltage fluctuates and, if the message recurs often, asking the grid operator to approve a change of the inverter's operating parameters before discussing it with SMA Service..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The inverter has deliberately reduced its power output because the grid voltage is too high, in order to help grid stability. SMA advises watching how often the grid voltage fluctuates and, if the message recurs often, asking the grid operator to approve a change of the inverter's operating parameters before discussing it with SMA Service.
Likely causes
- Grid voltage close to or above the permissible range
- Frequent grid voltage fluctuations at the connection point
What to check
- Check the grid voltage and observe how often fluctuations occur
- If the message appears often, ask the grid operator to approve a change of the operating parameters
- Discuss any approved parameter change with SMA Service
Parts implicated
grid connection
Sources (verbatim):
- https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (manual, retrieved 2026-11-21) p. 84
“Explanation: The inverter has reduced its power due to a too-high grid voltage to ensure grid stability.”
Paraphrased; verify against the manual for your exact model and serial number.