SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
SMA 3701: Residual current too high - check generator
Quick answerSMA 3701 means The inverter has detected a residual current caused by the brief grounding of the PV module, which points at an insulation fault on the array. SMA's measure is to check the PV system for ground faults..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The inverter has detected a residual current caused by the brief grounding of the PV module, which points at an insulation fault on the array. SMA's measure is to check the PV system for ground faults.
Likely causes
- Insulation fault to earth in the PV array
- Damaged DC cable or connector
- Moisture path from the array to earth
What to check
- Check the PV system for ground faults
- Isolate strings one at a time to locate the leaking string
- Have the faulty string repaired before it is reconnected
Parts implicated
PV modulesDC cablingRCD
Sources (verbatim):
- https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (manual, retrieved 2026-11-21) p. 90
“Explanation: The inverter has detected a residual current through brief grounding of the PV module.”
Paraphrased; verify against the manual for your exact model and serial number.