SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

SMA 3802: Residual current too high - check generator (DC overcurrent)

confidence: verifiedchecked 2026-11-21
Quick answerSMA 3802 means Events 3801 and 3802 carry the event message 'Residual current too high / Check generator', and SMA's explanation is that there is an overcurrent at the DC input which makes the inverter briefly interrupt feed-in operation. The remedy given is to check that the PV array has been correctly rated and wired if the message appears frequently..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

Events 3801 and 3802 carry the event message 'Residual current too high / Check generator', and SMA's explanation is that there is an overcurrent at the DC input which makes the inverter briefly interrupt feed-in operation. The remedy given is to check that the PV array has been correctly rated and wired if the message appears frequently.

Likely causes

  • PV array over-rated for the inverter's DC input
  • Incorrect string wiring or paralleling
  • DC-side fault or short circuit

What to check

  1. If the message is displayed frequently, ensure that the PV array has been correctly rated and wired
  2. Check the DC string wiring and the number of modules per string
  3. Contact SMA Service if the message persists after the array has been verified

Parts implicated

PV stringsDC cabling