SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

SMA 404: Grid incident - stand-alone grid or large frequency change

confidence: verifiedchecked 2026-11-21
Quick answerSMA 404 means Events 401 and 404 mean the inverter has disconnected from the utility grid because it detected a stand-alone (island) grid or a very large change in grid frequency. SMA asks the installer to establish that there is no power outage or work on the utility grid, to contact the grid operator if necessary, and to check the grid connection for significant short-term frequency fluctuations..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

Events 401 and 404 mean the inverter has disconnected from the utility grid because it detected a stand-alone (island) grid or a very large change in grid frequency. SMA asks the installer to establish that there is no power outage or work on the utility grid, to contact the grid operator if necessary, and to check the grid connection for significant short-term frequency fluctuations.

Likely causes

  • Utility grid outage or planned work on the grid
  • Islanding / stand-alone grid condition at the site
  • Large step change in grid frequency

What to check

  1. Make sure there is no power outage or work being done on the utility grid and contact the grid operator if necessary
  2. Check the grid connection for significant short-term frequency fluctuations

Parts implicated

grid connection