SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

SMA 507: Temperature AC frequency - power limited by high frequency

confidence: verifiedchecked 2026-11-21
Quick answerSMA 507 means The inverter has reduced its power output because the grid frequency is too high, in order to support grid stability. SMA advises monitoring the frequency fluctuations and, where the message appears often, requesting the grid operator's approval to change the operating parameters..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

The inverter has reduced its power output because the grid frequency is too high, in order to support grid stability. SMA advises monitoring the frequency fluctuations and, where the message appears often, requesting the grid operator's approval to change the operating parameters.

Likely causes

  • Grid frequency above the permissible range
  • Frequent grid frequency fluctuations at the connection point

What to check

  1. Check the grid frequency and observe how often fluctuations occur
  2. If the message appears often, ask the grid operator to approve a change of the operating parameters
  3. Discuss any approved change with SMA Service

Parts implicated

grid connection