SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
SMA 6509: Self-diagnosis - overtemperature
Quick answerSMA 6509 means Events 6501, 6502 and 6509 all mean the inverter has switched off because of excessive temperature. SMA's measures are to clean the cooling fins and air ducts with a soft brush, ensure the enclosure is sufficiently ventilated, keep it out of direct solar irradiation and make sure the maximum ambient temperature is not exceeded..
Escalation. If the fix goes beyond a non-invasive check or a software setting, or you are not sure the system is isolated, stop and call a qualified installer.
What it means
Events 6501, 6502 and 6509 all mean the inverter has switched off because of excessive temperature. SMA's measures are to clean the cooling fins and air ducts with a soft brush, ensure the enclosure is sufficiently ventilated, keep it out of direct solar irradiation and make sure the maximum ambient temperature is not exceeded.
Likely causes
- Blocked or dirty cooling fins and air ducts
- Insufficient ventilation around the enclosure
- Ambient temperature above the permitted maximum
- Direct solar irradiation on the inverter
What to check
- Clean the cooling fins on the rear of the enclosure and the air ducts on the top using a soft brush
- Ensure that the inverter has sufficient ventilation
- Ensure that the inverter is not exposed to direct solar irradiation
- Ensure the maximum ambient temperature is not exceeded
Parts implicated
heat sinkcooling
Sources (verbatim):
- https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (manual, retrieved 2026-11-21) p. 93
“Explanation: The inverter has switched off due to excessive temperature.”
Paraphrased; verify against the manual for your exact model and serial number.