SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
SMA 6801: Self-diagnosis - input A / input B defective (polarity error)
Quick answerSMA 6801 means Events 6801 and 6802 are reported as 'Self-diagnosis > Input A defective' and events 6901 and 6902 as 'Self-diagnosis > Input B defective'; the explanation SMA gives for all four is a polarity error on the inverter. The measures are to check whether a string is connected to input A (or B) and to contact Service..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
Events 6801 and 6802 are reported as 'Self-diagnosis > Input A defective' and events 6901 and 6902 as 'Self-diagnosis > Input B defective'; the explanation SMA gives for all four is a polarity error on the inverter. The measures are to check whether a string is connected to input A (or B) and to contact Service.
Likely causes
- PV string connected with reversed polarity to the DC input
- No string connected to the input although one is configured
- Input-stage fault on the DC input
What to check
- Check whether a string is connected to the input and that its polarity is correct
- Contact SMA Service if the message persists
Parts implicated
PV stringsDC input
Sources (verbatim):
- https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (manual, retrieved 2026-11-21) p. 95
“Explanation: Polarity error on the inverter.”
Paraphrased; verify against the manual for your exact model and serial number.