SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

SMA 6902: Self-diagnosis - input A / input B defective (polarity error)

confidence: verifiedchecked 2026-11-21
Quick answerSMA 6902 means Events 6801 and 6802 are reported as 'Self-diagnosis > Input A defective' and events 6901 and 6902 as 'Self-diagnosis > Input B defective'; the explanation SMA gives for all four is a polarity error on the inverter. The measures are to check whether a string is connected to input A (or B) and to contact Service..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

Events 6801 and 6802 are reported as 'Self-diagnosis > Input A defective' and events 6901 and 6902 as 'Self-diagnosis > Input B defective'; the explanation SMA gives for all four is a polarity error on the inverter. The measures are to check whether a string is connected to input A (or B) and to contact Service.

Likely causes

  • PV string connected with reversed polarity to the DC input
  • No string connected to the input although one is configured
  • Input-stage fault on the DC input

What to check

  1. Check whether a string is connected to the input and that its polarity is correct
  2. Contact SMA Service if the message persists

Parts implicated

PV stringsDC input