SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
SMA 7001: Fault sensor interior temperature
Quick answerSMA 7001 means Events 7001 and 7002 report 'Fault sensor interior temperature': a temperature sensor inside the inverter is defective, the inverter interrupts feed-in operation, and the cause must be determined by the Service. SMA's only measure is to contact Service..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
Events 7001 and 7002 report 'Fault sensor interior temperature': a temperature sensor inside the inverter is defective, the inverter interrupts feed-in operation, and the cause must be determined by the Service. SMA's only measure is to contact Service.
Likely causes
- Internal temperature sensor failed or disconnected
- Sensor harness or measurement circuit fault on the control board
What to check
- Note the event number and the inverter serial number
- Contact SMA Service; do not open the inverter to reseat the sensor
Parts implicated
temperature sensor
Sources (verbatim):
- https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (manual, retrieved 2026-11-21) p. 96
“Explanation: A temperature sensor in the inverter is defective and the inverter interrupts the feed-in operation. The cause must be determined by the Service.”
Paraphrased; verify against the manual for your exact model and serial number.