SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

SMA 701: Frequency not permitted - check parameter

confidence: verifiedchecked 2026-11-21
Quick answerSMA 701 means The grid frequency is not within the permissible range, so the inverter has disconnected from the utility grid. Unlike event 501, SMA additionally asks the installer to check the AC wiring between the inverter and the feed-in meter, and to get the grid operator's approval before changing operating parameters..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

The grid frequency is not within the permissible range, so the inverter has disconnected from the utility grid. Unlike event 501, SMA additionally asks the installer to check the AC wiring between the inverter and the feed-in meter, and to get the grid operator's approval before changing operating parameters.

Likely causes

  • Grid frequency outside the permissible range
  • AC wiring fault between the inverter and the feed-in meter
  • Operating parameters not matching the local grid code

What to check

  1. Check the AC wiring from the inverter to the feed-in meter
  2. Check the grid frequency and observe how often fluctuations occur
  3. If the message appears often, ask the grid operator to approve a change of the operating parameters

Parts implicated

AC wiringfeed-in meter
Sources (verbatim):

Paraphrased; verify against the manual for your exact model and serial number.