SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)

SMA 8708: Timeout in communication for active power limitation

confidence: verifiedchecked 2026-11-21
Quick answerSMA 8708 means Communication to the system control is absent, so the inverter falls back either to the last received values or to a fixed percentage of its nominal power for active power limitation. SMA asks for the connection to the system manager to be checked for damage and pulled plugs..
Escalation. If the fix goes beyond a non-invasive check or a software setting, or you are not sure the system is isolated, stop and call a qualified installer.

What it means

Communication to the system control is absent, so the inverter falls back either to the last received values or to a fixed percentage of its nominal power for active power limitation. SMA asks for the connection to the system manager to be checked for damage and pulled plugs.

Likely causes

  • System manager offline or unreachable
  • Damaged or disconnected communication cable
  • Network fault between inverter and system manager

What to check

  1. Ensure that the connection to the system manager (e.g. Sunny Home Manager) is intact
  2. Check that no cables are damaged and no plugs have been pulled
  3. Confirm the fall-back active power limit is acceptable until communication is restored

Parts implicated

communicationsystem manager
Sources (verbatim):
  • https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (manual, retrieved 2026-11-21) p. 98
    “Explanation: Communication to the system control absent. Depending on the fallback setting, either the last received values will be retained or the active power will be limited to the set percentage value of the inverter nominal power.”

Paraphrased; verify against the manual for your exact model and serial number.