SMA Sunny Tripower 3.0 / 4.0 / 5.0 / 6.0 (STPxx-3AV-40)
SMA 8710: Timeout in communication for reactive power / cos phi setpoint
Quick answerSMA 8710 means Event 8709 is 'Timeout in communication for reactive power setpoint' and event 8710 is 'Timeout in communication for cos phi setpoint'. SMA's explanation is that communication to the system control is absent, so the inverter falls back to the last received values or to the configured set value, and it asks for the connection to the system manager (e.g. Sunny Home Manager) to be checked for damage and pulled plugs..
Escalation. If the fix goes beyond a non-invasive check or a software setting, or you are not sure the system is isolated, stop and call a qualified installer.
What it means
Event 8709 is 'Timeout in communication for reactive power setpoint' and event 8710 is 'Timeout in communication for cos phi setpoint'. SMA's explanation is that communication to the system control is absent, so the inverter falls back to the last received values or to the configured set value, and it asks for the connection to the system manager (e.g. Sunny Home Manager) to be checked for damage and pulled plugs.
Likely causes
- System manager offline or unreachable
- Damaged or disconnected communication cable
- Network fault between inverter and system manager
What to check
- Ensure that the connection to the system manager is intact
- Check that no cables are damaged and no plugs have been pulled
- Confirm the fall-back setpoint with the grid operator if the message persists
Parts implicated
communicationsystem manager
Sources (verbatim):
- https://files.sma.de/downloads/STP3-6-3AV-40-BE-en-22.pdf (manual, retrieved 2026-11-21) p. 98
“Explanation: Communication to the system control absent.”
Paraphrased; verify against the manual for your exact model and serial number.