SolarEdge single-phase and three-phase inverters (Europe & APAC)
SolarEdge 18x7F: IRCDMax (RCD current surge)
Quick answerSolarEdge 18x7F means The inverter detected an RCD current surge caused by insufficient insulation to ground. The addendum repeats the isolation-fault procedure: switch off, wait five minutes, disconnect AC and DC, then reconnect strings one at a time to find the faulty string, which only a certified installer may fix..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The inverter detected an RCD current surge caused by insufficient insulation to ground. The addendum repeats the isolation-fault procedure: switch off, wait five minutes, disconnect AC and DC, then reconnect strings one at a time to find the faulty string, which only a certified installer may fix.
Likely causes
- Insufficient insulation to ground in the PV array
- Damaged DC cable, connector or module
- Water ingress causing leakage to earth
What to check
- Turn the inverter ON/OFF switch OFF and wait five minutes for the capacitors to discharge
- Disconnect the AC breaker and the DC inputs
- Reconnect each DC string separately until the error reappears
- Do not reconnect a grounded string; a certified installer must repair it
Parts implicated
PV modulesDC cablingRCD
Sources (verbatim):
- https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (manual, retrieved 2026-11-21) p. 6
“IRCDMax RCD current surge.”
Paraphrased; verify against the manual for your exact model and serial number.