Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. Read the safety model.
SolarEdge single-phase and three-phase inverters (Europe & APAC)

SolarEdge 18x86: Isolation fault (single-phase, 18x86)

confidence: verifiedchecked 2026-11-21
Quick answerSolarEdge 18x86 means Single-phase inverters report the isolation fault as code 18x86 (the same row lists 2x19 and 8x58). The PV array is not properly isolated from earth, and only a certified PV installer may repair the faulty string..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

Single-phase inverters report the isolation fault as code 18x86 (the same row lists 2x19 and 8x58). The PV array is not properly isolated from earth, and only a certified PV installer may repair the faulty string.

Likely causes

  • Damaged module insulation
  • Damaged DC string cable or connector
  • Moisture path to earth

What to check

  1. Read the isolation resistance on the inverter status screen
  2. Isolate and test string by string to find the leakage
  3. Have a certified PV installer repair the faulty string

Parts implicated

PV modulesDC cabling
Sources (verbatim):

Paraphrased; verify against the manual for your exact model and serial number.