SolarEdge single-phase and three-phase inverters (Europe & APAC)
SolarEdge 2x11: Temperature too high
Quick answerSolarEdge 2x11 means The inverter's internal temperature exceeded its limit. The addendum says to verify proper inverter clearances and make sure the heat-sink fins are clean and unobstructed..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The inverter's internal temperature exceeded its limit. The addendum says to verify proper inverter clearances and make sure the heat-sink fins are clean and unobstructed.
Likely causes
- Blocked airflow around the inverter
- Dirty or obstructed heat-sink fins
- High ambient temperature at the mounting location
What to check
- Verify the clearances around the inverter match the installation guide
- Check that the heat-sink fins are clean and unobstructed
- Measure the ambient temperature at the mounting location
Parts implicated
heat sinkcooling
Sources (verbatim):
- https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (manual, retrieved 2026-11-21) p. 3
“Temperature Too High Over temperature Verify proper inverter clearances. Make sure the heat-sink fins are clean and unobstructed.”
Paraphrased; verify against the manual for your exact model and serial number.