SolarEdge single-phase and three-phase inverters (Europe & APAC)
SolarEdge 2x19: Isolation fault
Quick answerSolarEdge 2x19 means The inverter detected that the PV array is not properly isolated from earth. The addendum says to check the PV installation for isolation problems and ground leakage, and that only a certified PV installer may fix the faulty string before it is reconnected..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The inverter detected that the PV array is not properly isolated from earth. The addendum says to check the PV installation for isolation problems and ground leakage, and that only a certified PV installer may fix the faulty string before it is reconnected.
Likely causes
- Damaged module insulation or backsheet
- Damaged DC cable, connector or junction
- Water ingress or soiling creating a path to earth
What to check
- Check the PV installation for isolation problems and ground leakage
- Use the inverter's isolation status screen (R Iso) to find the leaking string
- Leave the faulty string disconnected until a certified PV installer repairs it
Parts implicated
PV modulesDC cablingpower optimizers
Sources (verbatim):
- https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (manual, retrieved 2026-11-21) p. 3
“Isolation Fault PV solar array is not properly isolated from ground earth.”
Paraphrased; verify against the manual for your exact model and serial number.