SolarEdge single-phase and three-phase inverters (Europe & APAC)
SolarEdge 2x9: AC current surge
Quick answerSolarEdge 2x9 means The inverter logged a surge on the AC current input, shown together with a Vac surge. The addendum says a ground current surge can be involved and tells you to check the AC connection to the inverter and to ask the grid operator about large surge sources or irregular loads near the site..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The inverter logged a surge on the AC current input, shown together with a Vac surge. The addendum says a ground current surge can be involved and tells you to check the AC connection to the inverter and to ask the grid operator about large surge sources or irregular loads near the site.
Likely causes
- AC voltage/current surge on the grid
- Irregular load or large surge source near the site
- Loose or damaged AC connection
What to check
- Check the AC connection to the inverter
- Ask the grid operator whether a large surge source or irregular load exists near the site
- If the grid is clean, contact SolarEdge Support
Parts implicated
AC wiring