SolarEdge single-phase and three-phase inverters (Europe & APAC)

SolarEdge 2xA: Ground current / RCD trip

confidence: verifiedchecked 2026-11-21
Quick answerSolarEdge 2xA means A residual-current (ground-fault) event was detected. The addendum explains that ground faults may occur when insulation to ground is insufficient, warns of electric shock hazard inside the cover, and gives a string-by-string procedure that only a qualified technician may carry out..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

A residual-current (ground-fault) event was detected. The addendum explains that ground faults may occur when insulation to ground is insufficient, warns of electric shock hazard inside the cover, and gives a string-by-string procedure that only a qualified technician may carry out.

Likely causes

  • Damaged or degraded module insulation
  • Damaged DC string cable or connector
  • Moisture or soiling creating a leakage path to earth

What to check

  1. Turn the inverter ON/OFF switch to OFF and wait five minutes for the input capacitors to discharge
  2. Disconnect the AC breaker and the DC inputs
  3. Reconnect one DC string at a time until the error reappears to identify the faulty string
  4. Do not reconnect a string with a ground fault; a certified installer must repair it first

Parts implicated

PV modulesDC cablingRCD
Sources (verbatim):

Paraphrased; verify against the manual for your exact model and serial number.