SolarEdge single-phase and three-phase inverters (Europe & APAC)
SolarEdge 2xA: Ground current / RCD trip
Quick answerSolarEdge 2xA means A residual-current (ground-fault) event was detected. The addendum explains that ground faults may occur when insulation to ground is insufficient, warns of electric shock hazard inside the cover, and gives a string-by-string procedure that only a qualified technician may carry out..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
A residual-current (ground-fault) event was detected. The addendum explains that ground faults may occur when insulation to ground is insufficient, warns of electric shock hazard inside the cover, and gives a string-by-string procedure that only a qualified technician may carry out.
Likely causes
- Damaged or degraded module insulation
- Damaged DC string cable or connector
- Moisture or soiling creating a leakage path to earth
What to check
- Turn the inverter ON/OFF switch to OFF and wait five minutes for the input capacitors to discharge
- Disconnect the AC breaker and the DC inputs
- Reconnect one DC string at a time until the error reappears to identify the faulty string
- Do not reconnect a string with a ground fault; a certified installer must repair it first
Parts implicated
PV modulesDC cablingRCD
Sources (verbatim):
- https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (manual, retrieved 2026-11-21) p. 2
“Ground Current - RCD Ground faults may occur due to insufficient insulation to the ground.”
Paraphrased; verify against the manual for your exact model and serial number.