SolarEdge single-phase and three-phase inverters (Europe & APAC)
SolarEdge 3x11: Arc fault detected
Quick answerSolarEdge 3x11 means The inverter's arc-fault detector tripped: a DC arc was detected in the PV array. SolarEdge refers the installer to its arc-fault detection application note for the inspection and repair procedure..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The inverter's arc-fault detector tripped: a DC arc was detected in the PV array. SolarEdge refers the installer to its arc-fault detection application note for the inspection and repair procedure.
Likely causes
- Series or parallel DC arc in a string connector or cable
- Damaged module junction box or optimizer lead
- Loose DC connector under load
What to check
- Follow the arc-fault detection application note before re-energising
- Inspect string connectors, optimizer leads and module junction boxes for arcing
- Repair or replace the damaged DC component; do not reset repeatedly
Parts implicated
DC connectorspower optimizersPV modules
Sources (verbatim):
- https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (manual, retrieved 2026-11-21) p. 5
“Arc Fault Detected Refer to http://www.solaredge.com/sites/default/files/arc_ fault_detection_application_note.pdf”
Paraphrased; verify against the manual for your exact model and serial number.