SolarEdge single-phase and three-phase inverters (Europe & APAC)

SolarEdge 3x6D: Internal RGM error

confidence: verifiedchecked 2026-11-21
Quick answerSolarEdge 3x6D means An internal revenue-grade meter (RGM) error was reported. The addendum says to check the energy meter CT wiring..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

An internal revenue-grade meter (RGM) error was reported. The addendum says to check the energy meter CT wiring.

Likely causes

  • CT (current transformer) wiring reversed, open or loose
  • CT ratio or meter configuration mismatch

What to check

  1. Check the Energy Meter CT wiring against the meter installation guide
  2. Confirm CT orientation and that all phases are wired
  3. Re-commission the meter and clear the error

Parts implicated

energy meterCTs
Sources (verbatim):