SolarEdge single-phase and three-phase inverters (Europe & APAC)
SolarEdge 8x34: DC voltage too high (surge, three-phase)
Quick answerSolarEdge 8x34 means A three-phase inverter saw a DC input over-voltage (codes 8x34/8x35/8x37), normally a surge that the SolarEdge system should clear. If it persists, isolate, wait five minutes and locate the malfunctioning string..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
A three-phase inverter saw a DC input over-voltage (codes 8x34/8x35/8x37), normally a surge that the SolarEdge system should clear. If it persists, isolate, wait five minutes and locate the malfunctioning string.
Likely causes
- PV string too long for the DC input range
- Power optimizer failure
- DC surge or loose string connection
What to check
- Switch the inverter OFF, wait five minutes and check the safety voltage
- Locate the malfunctioning string and recheck its connections
- Follow the Power Optimizer Troubleshooting section of the installation guide
Parts implicated
PV stringspower optimizers
Sources (verbatim):
- https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (manual, retrieved 2026-11-21) p. 2
“DC Voltage Too High (surge) The SolarEdge system normally eliminates DC overvoltage errors.”
Paraphrased; verify against the manual for your exact model and serial number.