SolarEdge 8x34: DC voltage too high (surge, three-phase)

confidence: verifiedchecked 2026-11-21
Quick answerSolarEdge 8x34 means A three-phase inverter saw a DC input over-voltage (codes 8x34/8x35/8x37), normally a surge that the SolarEdge system should clear. If it persists, isolate, wait five minutes and locate the malfunctioning string..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

A three-phase inverter saw a DC input over-voltage (codes 8x34/8x35/8x37), normally a surge that the SolarEdge system should clear. If it persists, isolate, wait five minutes and locate the malfunctioning string.

Likely causes

  • PV string too long for the DC input range
  • Power optimizer failure
  • DC surge or loose string connection

What to check

  1. Switch the inverter OFF, wait five minutes and check the safety voltage
  2. Locate the malfunctioning string and recheck its connections
  3. Follow the Power Optimizer Troubleshooting section of the installation guide

Parts implicated

PV stringspower optimizers