SolarEdge single-phase and three-phase inverters (Europe & APAC)

SolarEdge 8x42: AC voltage too high (line 1/2/3, three-phase)

confidence: verifiedchecked 2026-11-21
Quick answerSolarEdge 8x42 means The AC grid voltage on one line exceeded the country limit (codes 8x42/8x43/8x44). The addendum says to verify the country setting, consult the grid operator and, if local authorities permit, change the grid protection values..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

The AC grid voltage on one line exceeded the country limit (codes 8x42/8x43/8x44). The addendum says to verify the country setting, consult the grid operator and, if local authorities permit, change the grid protection values.

Likely causes

  • Grid over-voltage above the country limit
  • Wrong country/grid-code setting

What to check

  1. Verify the inverter is set to the correct country
  2. Consult the grid operator
  3. Change grid protection values only if permitted by local authorities

Parts implicated

AC wiring