SolarEdge single-phase and three-phase inverters (Europe & APAC)

SolarEdge 8x58: Isolation fault (three-phase)

confidence: verifiedchecked 2026-11-21
Quick answerSolarEdge 8x58 means Three-phase inverters report the isolation fault as code 8x58. The PV array is not properly isolated from earth; check the installation for isolation problems and ground leakage, and have a certified installer fix the string..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

Three-phase inverters report the isolation fault as code 8x58. The PV array is not properly isolated from earth; check the installation for isolation problems and ground leakage, and have a certified installer fix the string.

Likely causes

  • Damaged module insulation
  • Damaged DC string cable or connector
  • Moisture or soiling leakage path

What to check

  1. Check the PV installation for isolation problems and ground leakage
  2. Isolate strings one at a time to locate the fault
  3. Only a certified PV installer may repair and reconnect the faulty string

Parts implicated

PV modulesDC cabling
Sources (verbatim):

Paraphrased; verify against the manual for your exact model and serial number.