SolarEdge 8x58: Isolation fault (three-phase)
Quick answerSolarEdge 8x58 means Three-phase inverters report the isolation fault as code 8x58. The PV array is not properly isolated from earth; check the installation for isolation problems and ground leakage, and have a certified installer fix the string..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
Three-phase inverters report the isolation fault as code 8x58. The PV array is not properly isolated from earth; check the installation for isolation problems and ground leakage, and have a certified installer fix the string.
Likely causes
- Damaged module insulation
- Damaged DC string cable or connector
- Moisture or soiling leakage path
What to check
- Check the PV installation for isolation problems and ground leakage
- Isolate strings one at a time to locate the fault
- Only a certified PV installer may repair and reconnect the faulty string
Parts implicated
PV modulesDC cabling
Sources (verbatim):
- https://web.archive.org/web/20230202122919/https://knowledge-center.solaredge.com/sites/kc/files/se-inverter-installation-guide-error-codes.pdf (manual, retrieved 2026-11-21) p. 3
“Isolation Fault PV solar array is not properly isolated from ground earth.”
Paraphrased; verify against the manual for your exact model and serial number.