Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. Read the safety model.
Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

Victron Err 1: Battery temperature too high

confidence: verifiedchecked 2026-11-21
Quick answerVictron Err 1 means The charger has stopped charging because the battery temperature is above the safe limit, to prevent battery damage. The temperature comes from an external sensor (Smart Battery Sense or BMV) or from the charger's own measurement..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

The charger has stopped charging because the battery temperature is above the safe limit, to prevent battery damage. The temperature comes from an external sensor (Smart Battery Sense or BMV) or from the charger's own measurement.

Likely causes

  • Battery operating above its safe temperature range
  • Faulty or misplaced temperature sensor

What to check

  1. Confirm the battery temperature reading in VictronConnect and let the battery cool
  2. Check that the temperature sensor is correctly placed and connected

Parts implicated

temperature sensorbattery
Sources (verbatim):

Paraphrased; verify against the manual for your exact model and serial number.