Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Victron Err 1: Battery temperature too high
Quick answerVictron Err 1 means The charger has stopped charging because the battery temperature is above the safe limit, to prevent battery damage. The temperature comes from an external sensor (Smart Battery Sense or BMV) or from the charger's own measurement..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The charger has stopped charging because the battery temperature is above the safe limit, to prevent battery damage. The temperature comes from an external sensor (Smart Battery Sense or BMV) or from the charger's own measurement.
Likely causes
- Battery operating above its safe temperature range
- Faulty or misplaced temperature sensor
What to check
- Confirm the battery temperature reading in VictronConnect and let the battery cool
- Check that the temperature sensor is correctly placed and connected
Parts implicated
temperature sensorbattery
Sources (verbatim):
- https://www.victronenergy.com/live/mppt-error-codes (vendor_kb, retrieved 2026-11-21) § Err 1 - Battery temperature too high
“This error will auto-reset after the battery temperature has dropped.”
Paraphrased; verify against the manual for your exact model and serial number.