Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Victron Err 11: Battery high ripple voltage
Quick answerVictron Err 11 means The DC battery voltage has excessive ripple, usually from loose or undersized DC cabling. Continuous high ripple shortens inverter life; the unit retries, then locks out after repeated shutdowns..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The DC battery voltage has excessive ripple, usually from loose or undersized DC cabling. Continuous high ripple shortens inverter life; the unit retries, then locks out after repeated shutdowns.
Likely causes
- Loose DC cable connections
- Undersized DC wiring
- High inverter load
What to check
- Check and tighten DC cable connections (system isolated)
- Confirm DC cable size matches the manual for the current
Parts implicated
DC cabling
Sources (verbatim):
- https://www.victronenergy.com/live/mppt-error-codes (vendor_kb, retrieved 2026-11-21) § Err 11 - Battery high ripple voltage
“High DC ripple is usually caused by loose DC cable connections and/or too thin DC wiring.”
Paraphrased; verify against the manual for your exact model and serial number.