Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Victron Err 20: Maximum Bulk-time exceeded
Quick answerVictron Err 20 means The charger did not reach absorption voltage within the bulk-time limit (10 hours on Skylla AC chargers), so it stopped to protect against a shorted cell. On older solar chargers, updating firmware removes the obsolete feature..
Escalation. If the fix goes beyond a non-invasive check or a software setting, or you are not sure the system is isolated, stop and call a qualified installer.
What it means
The charger did not reach absorption voltage within the bulk-time limit (10 hours on Skylla AC chargers), so it stopped to protect against a shorted cell. On older solar chargers, updating firmware removes the obsolete feature.
Likely causes
- Shorted or failing cell
- Battery not reaching absorption voltage within the time limit
- Outdated charger firmware (solar chargers)
What to check
- Update solar charger firmware to latest, then reset to factory defaults and reconfigure
- For AC chargers, test the battery for a shorted cell
Parts implicated
batteryfirmware
Sources (verbatim):
- https://www.victronenergy.com/live/mppt-error-codes (vendor_kb, retrieved 2026-11-21) § Err 20 - Maximum Bulk-time exceeded
“Solar Chargers The maximum bulk time protection is a feature that was in the chargers when they were just released (2015 or earlier) and later the feature was removed.”
Paraphrased; verify against the manual for your exact model and serial number.