Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. Read the safety model.
Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

Victron Err 20: Maximum Bulk-time exceeded

confidence: verifiedchecked 2026-11-21
Quick answerVictron Err 20 means The charger did not reach absorption voltage within the bulk-time limit (10 hours on Skylla AC chargers), so it stopped to protect against a shorted cell. On older solar chargers, updating firmware removes the obsolete feature..
Escalation. If the fix goes beyond a non-invasive check or a software setting, or you are not sure the system is isolated, stop and call a qualified installer.

What it means

The charger did not reach absorption voltage within the bulk-time limit (10 hours on Skylla AC chargers), so it stopped to protect against a shorted cell. On older solar chargers, updating firmware removes the obsolete feature.

Likely causes

  • Shorted or failing cell
  • Battery not reaching absorption voltage within the time limit
  • Outdated charger firmware (solar chargers)

What to check

  1. Update solar charger firmware to latest, then reset to factory defaults and reconfigure
  2. For AC chargers, test the battery for a shorted cell

Parts implicated

batteryfirmware
Sources (verbatim):
  • https://www.victronenergy.com/live/mppt-error-codes (vendor_kb, retrieved 2026-11-21) § Err 20 - Maximum Bulk-time exceeded
    “Solar Chargers The maximum bulk time protection is a feature that was in the chargers when they were just released (2015 or earlier) and later the feature was removed.”

Paraphrased; verify against the manual for your exact model and serial number.