Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

Victron Err 29: Over-charge protection

confidence: verifiedchecked 2026-11-21
Quick answerVictron Err 29 means The charger disconnected the battery to protect it from over-charging; it resets once battery voltage drops below float..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

The charger disconnected the battery to protect it from over-charging; it resets once battery voltage drops below float.

Likely causes

  • Oversized PV array wired with too many panels in series
  • Battery settings (absorption/float) not matching the installation
  • Another charger raising the battery voltage

What to check

  1. Check PV array configuration and re-wire panels in parallel to reduce voltage if needed
  2. Verify absorption and float voltage settings match the battery
  3. Check for other chargers on the battery

Parts implicated

batteryPV array
Sources (verbatim):