Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Victron Err 33: PV over-voltage
Quick answerVictron Err 33 means The PV open-circuit voltage is critical for this charger (too high for its rating); the error resets once PV voltage drops to a safe level..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The PV open-circuit voltage is critical for this charger (too high for its rating); the error resets once PV voltage drops to a safe level.
Likely causes
- PV array open-circuit voltage too high for the charger
- Too many panels in series
What to check
- Check the PV array configuration against the charger's max PV voltage
- Re-organise panels (fewer in series) if required
Parts implicated
PV array
Sources (verbatim):
- https://www.victronenergy.com/live/mppt-error-codes (vendor_kb, retrieved 2026-11-21) § Err 33 - PV over-voltage
“This error will auto-reset after PV-voltage has dropped to safe limit.”
Paraphrased; verify against the manual for your exact model and serial number.