Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. Read the safety model.
Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

Victron Err 35: PV over-power

confidence: verifiedchecked 2026-11-21
Quick answerVictron Err 35 means The internal DC voltage is too high (or, on older firmware, a known bug). Update firmware first; the error usually auto-resets..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

The internal DC voltage is too high (or, on older firmware, a known bug). Update firmware first; the error usually auto-resets.

Likely causes

  • Firmware older than v1.08 (MPPT RS / Inverter RS / Multi RS)
  • Internal DC voltage too high

What to check

  1. Update firmware to v1.08 or newer
  2. If it persists, isolate all power, wait 3 minutes, repower

Parts implicated

firmwarecharge controller
Sources (verbatim):

Paraphrased; verify against the manual for your exact model and serial number.