Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. Read the safety model.
Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

Victron Err 38: PV input shutdown (battery over-charge protection)

confidence: verifiedchecked 2026-11-21
Quick answerVictron Err 38 means The PV input was internally shorted to protect the battery from over-charging. Check firmware and the battery voltage setting before other troubleshooting..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

The PV input was internally shorted to protect the battery from over-charging. Check firmware and the battery voltage setting before other troubleshooting.

Likely causes

  • Battery voltage (12/24/36/48 V) set incorrectly
  • Another device on the battery configured to a higher voltage
  • Outdated firmware

What to check

  1. Update to the latest firmware
  2. Verify the battery voltage setting in VictronConnect
  3. Disconnect panels then battery, wait 3 minutes, reconnect battery then panels

Parts implicated

batteryPV input
Sources (verbatim):
  • https://www.victronenergy.com/live/mppt-error-codes (vendor_kb, retrieved 2026-11-21) § Err 38, Err 39 and Err 80 to Err 87 - PV Input shutdown
    “When these errors show, the PV Input is internally shorted in order to protect the battery from over-charging.”

Paraphrased; verify against the manual for your exact model and serial number.