Victron Err 39: PV input shutdown (over-voltage, auto-recover)
Quick answerVictron Err 39 means The PV input was internally shorted to protect the battery from over-charging; the charger resumes automatically once battery voltage drops below its maximum voltage setting..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The PV input was internally shorted to protect the battery from over-charging; the charger resumes automatically once battery voltage drops below its maximum voltage setting.
Likely causes
- Battery voltage setting incorrect
- Another device on the battery set to a higher voltage
- Outdated firmware
What to check
- Update firmware
- Verify battery voltage settings
- Confirm the error clears as battery voltage falls
Parts implicated
batteryPV input
Sources (verbatim):
- https://www.victronenergy.com/live/mppt-error-codes (vendor_kb, retrieved 2026-11-21) § Err 38, Err 39 and Err 80 to Err 87 - PV Input shutdown
“When these errors show, the PV Input is internally shorted in order to protect the battery from over-charging.”