Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Victron Err 42: PV isolation failure (ground leakage)
Quick answerVictron Err 42 means Ground leakage current in the PV array exceeds the 30 mA limit..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
Ground leakage current in the PV array exceeds the 30 mA limit.
Likely causes
- Damaged PV cabling or panel insulation
- Moisture or ground leakage in the array
What to check
- Check PV array cabling and panel isolation
- Disconnect the PV array with the PV switch to resume AC operation
Parts implicated
PV cablingpanels
Sources (verbatim):
- https://www.victronenergy.com/live/mppt-error-codes (vendor_kb, retrieved 2026-11-21) § Err 42 - PV isolation failure
“The ground leakage current in the PV array exceeds the allowed 30mA limit. Check the PV array cabling and panel isolation. Consider disconnecting the PV array using the PV switch to resume AC operation.”