Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. Read the safety model.
Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

Victron Err 43: Ground fault detected

confidence: verifiedchecked 2026-11-21
Quick answerVictron Err 43 means The voltage between Neutral and Ground is too high. On grid-connected systems this usually means the installation ground is missing/incorrect or Line and Neutral are swapped; on island systems the ground relay may be damaged. It does not auto-reset..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.

What it means

The voltage between Neutral and Ground is too high. On grid-connected systems this usually means the installation ground is missing/incorrect or Line and Neutral are swapped; on island systems the ground relay may be damaged. It does not auto-reset.

Likely causes

  • Missing or incorrectly connected ground wire
  • Line and Neutral swapped in the installation
  • Damaged ground relay (island operation)

What to check

  1. Check the installation ground and Line/Neutral wiring
  2. Restart the unit with the power switch after correcting the wiring

Parts implicated

ground wiringground relay
Sources (verbatim):