Qualified installer only. High-voltage, grid-tied and battery systems can kill. Do not open energised DC/AC equipment. Read the safety model.
Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC

Victron Err 5: Remote temperature sensor failure (connection lost)

confidence: verifiedchecked 2026-11-21
Quick answerVictron Err 5 means The charger has lost connection to the remote temperature sensor it was previously reading..
Escalation. If the fix goes beyond a non-invasive check or a software setting, or you are not sure the system is isolated, stop and call a qualified installer.

What it means

The charger has lost connection to the remote temperature sensor it was previously reading.

Likely causes

  • Loose or disconnected T-sense wiring
  • Failed temperature sensor

What to check

  1. Check the T-sense connector and cable
  2. Reconnect and confirm the reading returns in VictronConnect

Parts implicated

temperature sensor
Sources (verbatim):
  • https://www.victronenergy.com/live/mppt-error-codes (vendor_kb, retrieved 2026-11-21) § Err 5 - Remote temperature sensor failure (connection lost)
    “Check if the T-sense connector is properly connected to a remote temperature sensor. This error will not auto-reset.”

Paraphrased; verify against the manual for your exact model and serial number.