Victron Err 50: Inverter overload / peak current
Quick answerVictron Err 50 means The inverter shut down because the load's inrush or steady current exceeded the over-current trip level. After three restarts with another overload it stays off until manually restarted..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The inverter shut down because the load's inrush or steady current exceeded the over-current trip level. After three restarts with another overload it stays off until manually restarted.
Likely causes
- Motor or pump inrush current exceeding the trip level
- Excessive AC load
What to check
- Reduce the AC load (switch off or disconnect appliances)
- Restart the inverter if it locked out
Parts implicated
AC loads
Sources (verbatim):
- https://www.victronenergy.com/live/mppt-error-codes (vendor_kb, retrieved 2026-11-21) § Err 50, Err 52 - Inverter overload, Inverter peak current
“Some loads like motors or pumps draw large inrush currents in a start-up situation.”