Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Victron Err 6: Remote battery voltage sense failure
Quick answerVictron Err 6 means The remote battery voltage sense input is invalid, most commonly because the V-sense connector is wired in reverse polarity..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The remote battery voltage sense input is invalid, most commonly because the V-sense connector is wired in reverse polarity.
Likely causes
- V-sense connector wired with reversed polarity
- Faulty sense wiring
What to check
- Check the V-sense connector polarity against the battery terminals
- Reconnect and confirm the reading
Parts implicated
voltage sense wiring
Sources (verbatim):
- https://www.victronenergy.com/live/mppt-error-codes (vendor_kb, retrieved 2026-11-21) § Err 6, Err 7 - Remote battery voltage sense failure
“Check if the V-sense connector is properly connected to the battery terminals. Most likely cause: the remote V-sense connector is connected in reverse polarity to the BAT+ or BAT- terminals.”
Paraphrased; verify against the manual for your exact model and serial number.