Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Victron Err 67: BMS connection lost
Quick answerVictron Err 67 means The charger is configured to be controlled by a BMS but is not receiving BMS messages, so it reduces output to the battery base voltage as a safety measure..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The charger is configured to be controlled by a BMS but is not receiving BMS messages, so it reduces output to the battery base voltage as a safety measure.
Likely causes
- Disconnected or faulty BMS communication cable
- BMS switched off or faulty
What to check
- Check the connection between the charger and the BMS
- Reconfigure to standalone mode if the charger is no longer used with a BMS
Parts implicated
BMScommunication cable
Sources (verbatim):
- https://www.victronenergy.com/live/mppt-error-codes (vendor_kb, retrieved 2026-11-21) § Err 67 - BMS Connection lost
“This error shows when the charger is configured to be controlled by a BMS, but does not receive any BMS control messages.”
Paraphrased; verify against the manual for your exact model and serial number.