Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Victron Err 68: Network misconfigured
Quick answerVictron Err 68 means The charger detects multiple conflicting network sources (VE.Can and VE.Direct) with the same priority sending the same information..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
The charger detects multiple conflicting network sources (VE.Can and VE.Direct) with the same priority sending the same information.
Likely causes
- Both VE.Direct and VE.Can connected at the same time
- Firmware older than v1.48 (SmartSolar VE.Direct)
What to check
- Update firmware
- Remove one of the two cables (VE.Direct or VE.Can)
Parts implicated
communication cabling
Sources (verbatim):
- https://www.victronenergy.com/live/mppt-error-codes (vendor_kb, retrieved 2026-11-21) § Err 68 - Network misconfigured
“Applies to SmartSolar/BlueSolar MPPTs VE.Can (FW version v1.04 or higher) and SmartSolar VE.Direct MPPTs (FW version v1.47).”
Paraphrased; verify against the manual for your exact model and serial number.