Victron SmartSolar / BlueSolar MPPT charge controllers, Inverter RS / Multi RS, Orion Smart DC-DC
Victron Info 66: Incompatible device
Quick answerVictron Info 66 means The controller is paralleled to another controller with different settings or a different charge algorithm, or MPPTs are on VE.Smart networking while connected to a GX device..
Escalation. If the fix goes beyond a non-invasive check or a software setting, or you are not sure the system is isolated, stop and call a qualified installer.
What it means
The controller is paralleled to another controller with different settings or a different charge algorithm, or MPPTs are on VE.Smart networking while connected to a GX device.
Likely causes
- Mismatched settings or charge algorithms between parallel controllers
- VE.Smart networking enabled while connected to a GX device
What to check
- Match all settings and update firmware on all chargers
- Disable VE.Smart networking and use DVCC on the GX device instead
Parts implicated
None listed
Sources (verbatim):
- https://www.victronenergy.com/live/mppt-error-codes (vendor_kb, retrieved 2026-11-21) § Information 66 - Incompatible device
“The controller is being paralleled to another controller that has different settings and/or a different charge algorithm.”
Paraphrased; verify against the manual for your exact model and serial number.