Victron MultiPlus / Quattro / MultiPlus-II / EasySolar-II (VE.Bus inverter/charger)
Victron VE.Bus Error 11: Relay test fault (installation or relay failure)
Quick answerVictron VE.Bus Error 11 means A failed automatic self-test of the MultiPlus-II / EasySolar-II relays; usually an installation or wiring issue, but can be a hardware failure..
Qualified installer only. This fault touches the AC grid connection, battery bank, DC bus, or an internal power stage. Isolate and verify de-energised, then escalate to a qualified installer/electrician.
What it means
A failed automatic self-test of the MultiPlus-II / EasySolar-II relays; usually an installation or wiring issue, but can be a hardware failure.
Likely causes
- Earth not grounded per local grid rules, or Earth connected to Neutral in the unit
- AC-in Line/Neutral inverted
- Leakage between load, neutral and ground
- Faulty relay
What to check
- Update firmware to latest
- Verify the earth connection and that Earth is not connected to Neutral in the unit
- Isolate AC-out (disconnect L and N) and test
- Check the Neutral-out / Neutral-in connection per grid code
- Check Line/Neutral are not swapped
Parts implicated
relayAC wiringearthing
Sources (verbatim):
- https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes (vendor_kb, retrieved 2026-11-21) § Error 11 - Relay Test Fault - Installation error or possibly relay failure
“Error 11 indicates a failed automatic self-test of the MultiPlus-II or EasySolar-II relays.”
Paraphrased; verify against the manual for your exact model and serial number.